Chromatography

Total products

- 9

Gas Chromatography MGC-1A

Sample injector temperature range RT +7 °C ~ 420 °C
Power supply AC 220 V ± 10 % ; 50 Hz / 60 Hz
Dimensions ( W x D x H ) 1020 x 660 x 740 mm
Gross weight 82 kg

Gas Chromatography MGC-1B

Sample injector temperature range
Power supply AC 110 V / 220 V ± 10 % ; 50 Hz / 60 Hz
Dimensions ( W x D x H ) 800 x 570 x 650 mm
Gross weight 75 kg

Ion Chromatography MICG-1A

Dimensions (L x W x H) 325 x 400 x 500 mm
Weight 21 kgs
Whole plastic pipeline Made of PEEK material
Six way valve PEEK material FLOM series of six way valve, pressure 5000 psi, a signal automatic collecting and flow function

Ion Chromatography MICG-1B

Dimensions (L x W x H) 350 x 470 x 510 mm
Weight 26 kgs
Whole plastic pipeline Made of PEEK material
Six way valve Rheodyne electromagnetic six-way valve, compression resistance of 7000 psi, collect signals automatically.

Ion Chromatography MICG-1C

Dimensions (L x W x H) 350 x 470 x 650 mm
Weight 34 kgs
Whole plastic pipeline Made of PEEK material
Six way valve Rheodyne electromagnetic six-way valve, compression resistance of 7000 psi, collect signals automatically

Ion Chromatography MICG-1D

Dimensions (L x W x H) 500 x 570 x 510 mm
Weight 40 kgs
Whole plastic pipeline Made of PEEK material
Six way valve Rheodyne electromagnetic six-way valve, compression resistance of 7000 psi, collect signals automatically.

Gas chromatography mass spectrometry MGCMS-1A

Gas Chromatography Specifications
Model No GCMZ-A1
Flow rate 1 ~ 1.5 ml / min
Maximum flow rate 10 ml / min
Inlet temperature
Pressure range 0 ~ 100 psi
Heating rate
Room temperature
Pressure control mode Electronic pressure control ( Supports CV and CC )
Split mode Split / split less
Split ratio 16:01:00
Temperature programming 7 stages / 8 platforms
Auto sampler Optional
Mass Spectrometry Specifications
Model No MSMZ-1A
Mass range 1.5 ~ 1000 amu
Ion – source temperature 100 degree Celcius ~ 350 degree Celcius
GC-MS interface temperature 450 degree Celcius
Scan rate Upto 10000 amu/s
Stability 0.10 amu / 48 hrs.
Filament emission current 0 ~ 350 micro Ampere
EI source ionization energy 5 eV ~ 250 eV
Resolution Unit resolution
Detector High energy dynode electron multiplier
Sensitivity Full scan ( S / N is ≥ 30 : 1 )
Vacuum Turbo molecular pump ( 67 L/s )

Liquid Chromatography MLC-1A

Pump
System Gradient
Flow rate range 0.001 ~ 9.999 mL / min
Flow rate accuracy ≤ ± 0.5 % ( 1 mL / min, water, room temperature )
Flow rate precision RSD ≤ 0.08 % ( 1 mL / min, water, room temperature )
Pressure range ≤ 42 MPa
Dimensions 470 * 380 * 300 mm
Net Weight 8 kgs
Gross Weight 10 kgs
Detector
Lamp Deuterium lamp
Wavelength range 190 nm ~ 700 nm
Baseline noise ≤ 8*10-6 AU
Baseline drift ≤ 1 × 10-4 AU / h
Detection Limit 4×10-9 g/ml ( Naphthalene / methyl alcohol solvent )
Wavelength accuracy ±1 nm
Dimensions 470*380*400 mm
Net Weight 8 kgs
Gross Weight 10 kgs

Liquid Chromatography MLC-1B

Pump
System Isocratic
Flow rate range 0.001 ~ 9.999 mL / min
Flow rate accuracy ≤ ± 0.5 % ( 1 mL / min, water, room temperature )
Flow rate precision RSD ≤ 0.08 % ( 1 mL / min, water, room temperature )
Pressure range ≤ 42 MPa
Dimensions 470*380*300 mm
Net Weight 8 kgs
Gross Weight 10 kgs
Detector
Lamp Deuterium lamp
Wavelength range 191 nm ~ 700 nm
Baseline noise ≤ 8*10-6 AU
Baseline drift ≤ 1*10-4 AU / h
Detection Limit 4×10-9 g/ml ( Naphthalene / methyl alcohol solvent )
Wavelength accuracy ±1 nm
Dimensions 470*380*400 mm
Net Weight 8 kgs